Solar Cluster: Beware, I’m ARMed

Last night, I got home, having made a detour on my way into work past Jaycar Wooloongabba to replace the faulty PSU.
It was a pretty open-and-shut case, we took it out of the box, plugged it in, and sure enough, no fan.  After the saleswoman asked the advice of a co-worker, it was confirmed that the fan should be running.
It took some digging, but they found a replacement, and so it was boxed up (in the box I supplied, they didn’t have one), and I walked out the door with PSU No. 3.
I had to go straight to work, so took the PSU with me, and that evening, I loaded it into the top box to transport home on the bicycle.
I get home, and it’s first thing on my mind.  I unlock the top box, get it out, and still decked out in my cycling gear, helmet and all (needed the headlight to see down the back of the rack anyway), I get to work.
I put the ring lugs on, plug it into the wall socket and flick the switch.
Nothing.
Toggle the switch on the front, still nothing.
Tried the other socket on the outlet, unplugging the load, still nothing.  Did the 10km trip from Milton to The Gap kill it?
Frustrated, I figure I’ll switch a light on.  Funny… no lights.
I wander into the study… sure enough, the router, modem and switch are dead as doornails.  Wander out to the MDB outside, saw the main breaker was still on, and tried hitting the test button.  Nothing.
I wander back inside, switching the bike helmet for my old hard hat, since it looks as if I’ll need the headlight a bit longer, then take a sticky beak down the road to see if anyone else is facing the same issue.
Sure enough, I look down the street, everyone’s out.
So there goes my second attempt at bootstrapping Gentoo, and my old server’s uptime.
The power did return about an hour or so later.  The PSU was fine, you don’t think of the mains being out as the cause of your problems.
I’ll re-start my build, but I’m not going to lose another build to failing power.  Nope, had enough of that for a joke.
I could have rigged up a UPS to the TS-7670, but I already have one, and it’s in the very rack where it’ll get installed anyway.  Thus, no time like the present to install it.
I’ll have to configure the switch to present the right VLANs to the TS-7670, but once I do that, it’ll be able to take over the role of routing between the management VLAN and the main network.
I didn’t want to do this in a VM because that means exposing the hosts and the VMs to the management VLAN, meaning anyone who managed to compromise a host would have direct access to the BMCs on the other nodes.
This is not a network with high bandwidth demands, and so the TS-7670 with its 100Mbps Ethernet (built into the SoC; not via USB) is an ideal machine for this task.
Having done this, all that’s left to do is to create a 2GB dual-core VM which will receive the contents of the old server, then that server can be shut down, after 8 years of good service.  I’ll keep it around for storing the on-site backups, but now I can keep it asleep and just wake it up with Wake-on-LAN when I want to make a back-up.
This should make a dint in our electricity bill!
Other changes…

  • Looks like we’ll be upgrading the solar with the addition of another 120W panel.
  • I will be hooking up my other network switches, the ADSL router and ADSL modem up to the battery bank on the cluster, just got to get some suitable cable for doing so.
  • I have no faith in this third PSU, so already, I have a MeanWell HEP-600C coming.  We’ll wire up a suicide lead to it, and that can replace the Powertech MP-3089 + Redarc BCDC1225, as the MeanWell has a remote on/off feature I can use to control it.

Solar Cluster: Battery monitor computer ordered

I’ve taken the plunge and gotten a TS-7670 ordered in a DIN-rail mount for monitoring the battery.  Not sure what the shipping will be from Arizona to here, but I somehow doubt I’m up for more than AU$300 for this thing.  The unit itself will cost AU$250.

Some will argue that a Raspberry Pi or BeagleBone would be cheaper, and that would be correct, however by the time you’ve added a DIN-rail mount case, an RS-485 control board and a 12V to 5V step-down power converter, you’d be around that figure anyway.  Plus, the Raspberry Pi doesn’t give you schematics.  The BeagleBone does, but is also a more sophisticated beast.

The plan is I’ll spin a version of Gentoo Linux on it… possibly using the musl C library to keep memory usage down as I’ve gone the base model with 128MB RAM.  I’ll re-spin the kernel and U-Boot patches I have for the latest release.

There will be two functions looked after:

  • Access to the IPMI/L2 management network
  • Polling of the two DC power meters (still to be fully designed) via Modbus

It can report to a VM running on one of the hosts.  I believe collectd has the necessary bits and pieces to do this.  Failing that, I’ve written code before that polls Modbus… I write such code for a day job.

Solar Cluster: OpenNebula, DNS shennanigans and network documentation

OpenNebula is running now… I ended up re-loading my VM with Ubuntu Linux and throwing OpenNebula on that.  That works… and I can debug the issue with Gentoo later.

I still have to figure out corosync/heartbeat for two VMs, the one running OpenNebula, and the core router.  For now, the VMs are only set up to run on one node, but I can configure them on the other too… it’s then a matter of configuring libvirt to not start the instances at boot, and setting up the Linux-HA tools to figure out which node gets to fire up which VM.

The VM hosts are still running Gentoo however, and so far I’ve managed to get them to behave with OpenNebula.  A big part was disabling the authentication in libvirt, otherwise polkit generally made a mess of things from OpenNebula’s point of view.

That, and firewalld had to be told to open up ports for VNC/spice… I allocated 5900-6900… I doubt I’ll have that many VMs.

Last weekend I replaced the border router… previously this was a function of my aging web server, but now I have an ex-RAAF-base Advantech UNO-1150G industrial PC which is performing the routing function.  I tried to set it up with Gentoo, and while it worked, I found it wasn’t particularly stable due to limited memory (it only has 256MB RAM).  In the end, I managed to get OpenBSD 6.1/i386 running sweetly, so for now, it’s staying that way.

While the AMD Geode LX800 is no speed demon, a nice feature of this machine is it’s happy with any voltage between 9 and 32V.

The border router was also given the responsibility of managing the domain: I did this by installing ISC BIND9 from ports and copying across the config from Linux.  This seemed to be working, and so I left it.  Big mistake, turns out bind9 didn’t think it was authoritative, and so refused to handle AXFRs with my slaves.

I was using two different slave DNS providers, puck.nether.net and Roller Network, both at the time of subscription being freebies.  Turns out, when your DNS goes offline, puck.nether.net responds by disabling your domain then emailing you about it.  I received that email Friday morning… and so I wound up in a mad rush trying to figure out why BIND9 didn’t consider itself authoritative.

Since I was in a rush, I decided to tell the border router to just port-forward to the old server, which got things going until I could look into it properly.  It took a bit of tinkering with pf.conf, but eventually got that going, and the crisis was averted.  Re-enabling the domains on puck.nether.net worked, and they stayed enabled.

It was at that time I discovered that Roller Network had decided to make their slave DNS a paid offering.  Fair enough, these things do cost money… At first I thought, well, I’ll just pay for an account with them, until I realised their personal plans were US$5/month.  My workplace uses Vultr for hosting instances of their WideSky platform for customers… and aside from the odd hiccup, they’ve been fine.  US$5/month VPS which can run almost anything trumps US$5/month that only does secondary DNS, so out came the debit card for a new instance in their Sydney data centre.

Later I might use it to act as a caching front-end and as a secondary mail exchanger… but for now, it’s a DIY secondary DNS.  I used their ISO library to install an OpenBSD 6.1 server, and managed to nut out nsd to act as a secondary name server.

Getting that going this morning, I was able to figure out my DNS woes on the border router and got that running, so after removing the port forward entries, I was able to trigger my secondary DNS at Vultr to re-transfer the domain and debug it until I got it working.

With most of the physical stuff worked out, it was time to turn my attention to getting virtual instances working.  Up until now, everything running on the VM was through hand-crafted VMs using libvirt directly.  This is painful and tedious… but for whatever reason, OpenNebula was not successfully deploying VMs.  It’d get part way, then barf trying to set up 802.1Q network interfaces.

In the end, I knew OpenNebula worked fine with bridges that were already defined… but I didn’t want to have to hand-configure each VLAN… so I turned to another automation tool in my toolkit… Ansible:

- hosts: compute
  tasks:
  - name: Configure networking
    template: src=compute-net.j2 dest=/etc/conf.d/net
# …
- hosts: compute
  tasks:
# …
  - name: Add symbolic links (instance VLAN interfaces)
    file: src=net.lo dest=/etc/init.d/net.bond0.{{item}} state=link
    with_sequence: start=128 end=193
  - name: Add symbolic links (instance VLAN bridges)
    file: src=net.lo dest=/etc/init.d/net.vlan{{item}} state=link
    with_sequence: start=128 end=193
# …
  - name: Make services start at boot (instance VLAN bridges)
    command: rc-update add net.vlan{{item}} default
    with_sequence: start=128 end=193 

That’s a snippet of the playbook… and it basically creates symbolic links from Gentoo’s net.lo for all the VLAN ports and bridges, then sets them up to start at boot.

In the compute-net.j2 file referenced above, I put in the following to enumerate all the configuration bits.

# Instance VLANs
{% for vlan in range(128,193) %}
config_vlan{{vlan}}="null"
config_bond0_{{vlan}}="null"
rc_net_vlan{{vlan}}_need="net.bond0.{{vlan}}"
{% endfor %}
# …
vlans_bond0="5 8 10{% for vlan in range(128,193) %} {{vlan}} {% endfor %}248 249 250 251 252"
vlans_bond1="253"
# …
# Instance VLANs
{% for vlan in range(128,193) %}
bridge_vlan{{vlan}}="bond0.{{vlan}}"
{% endfor %} 

The start and end ranges are a little off, but it saved a lot of work.

This naturally took a while for OpenRC to bring up… but it worked. Going back to OpenNebula, I told it what bridges to use, and before long I had my first instance… an OpenBSD router to link my personal VLAN to the DMZ.

I spent a bit of time re-working my routing tables after that… in fact, my network is getting big enough now I have to write some details down.  I spent a few hours documenting the effort:

That’s page 1 of about 15… yes my hand is sore… but at least now should I get run over by a bus, others have a fighting chance doing anything with the network without my technical input.

Solar Cluster: Networking

So, having got some instances going… I thought I better sort out the networking issues proper.  While it was working, I wanted to do a few things:

  1. Bring a dedicated link down from my room into the rack directly for redundancy
  2. Define some more VLANs
  3. Sort out the intermittent faults being reported by Ceph

I decided to tackle (1) first.  I have two 8-port Cisco SG-200 switches linked via a length of Cat5E that snakes its way from our study, through the ceiling cavity then comes up through a small hole in the floor of my room, near where two brush-tail possums call home.

I drilled a new hole next to where the existing cable entered, then came the fun of trying to feed the new cable along side the old one.  First attempt had the cable nearly coil itself just inside the cavity.  I tried to make a tool to grab the end of it, but it was well and truly out of reach.  I ended up getting the job done by taping the cable to a section of fibreglass tubing, feeding that in, taping another section of tubing to that, feed that in, etc… but then I ran out of tubing.

Luckily, a rummage around, and I found some rigid plastic that I was able to tape to the tubing, and that got me within a half-metre of my target.  Brilliant, except I forgot to put a leader cable through for next time didn’t I?

So more rummaging around for a length of suitable nylon rope, tape the rope to the Cat5E, haul the Cat5E out, then grab another length of rope and tape that to the end and use the nylon rope to haul everything back in.

The rope should be handy for when I come to install the solar panels.

I had one 16-way patch panel, so wound up terminating the rack-end with that, and just putting a RJ-45 on the end in my room and plugging that directly into the switch.  So on the shopping list will be some RJ-45 wall jacks.

The cable tester tells me I possibly have brown and white-brown switched, but never mind, I’ll be re-terminating it properly when I get the parts, and that pair isn’t used anyway.

The upshot: I now have a nice 1Gbps ring loop between the two SG-200s and the LGS326 in the rack.  No animals were harmed in the formation of this ring, although two possums were mildly inconvenienced.  (I call that payback for the times they’ve held the Marsupial Olympics at 2AM when I’m trying to sleep!)

Having gotten the physical layer sorted out, I was able to introduce the upstairs SG-200 to the new switch, then remove the single-port LAG I had defined on the downstairs SG-200.  A bit more tinkering going, and I had a nice redundant set-up: setting my laptop to ping one of the instances in the cluster over WiFi, I could unplug my upstairs trunk, wait a few seconds, plug it back in, wait some more, unplug the downstairs trunk, wait some more again, then plug in back in again, and not lose a single ICMP packet.

I moved my two switches and my AP over to the new management VLAN I had set up, along side the IPMI interfaces on the nodes.  The SG-200s were easy, aside from them insisting on one port being configured with a PVID equal to the management VLAN (I guess they want to ensure you don’t get locked out), it all went smoothly.

The AP though, a Cisco WAP4410N… not so easy.  In their wisdom, and unlike the SG-200s, the management VLAN settings page is separate from the IP interface page, so you can’t change both at the same time.  I wound up changing the VLAN, only to find I had locked myself out of it.  Much swearing at the cantankerous AP and wondering how could someone overlook such a fundamental requirement!  That, and the switch where the AP plugs in, helpfully didn’t add the management VLAN to the right port like I asked of it.

Once that was sorted out, I was able to configure an IP on the old subnet and move the AP across.

That just left dealing with the intermittent issues with Ceph.  My original intention with the cluster was to use 802.3AD so each node had two 2Gbps links.  Except: the LGS326-AU only supports 4 LAGs.  For me to do this, I need 10!

Thankfully, the bonding support in the Linux kernel has several other options available.  Switching from 802.3ad to balance-tlb, resolved the issue.

slaves_bond0="enp0s20f0 enp0s20f1"
slaves_bond1="enp0s20f2 enp0s20f3"
config_bond0="null"
config_bond1="null"
config_enp0s20f0="null"
config_enp0s20f1="null"
config_enp0s20f2="null"
config_enp0s20f3="null"
rc_net_bond0_need="net.enp0s20f0 net.enp0s20f1"
rc_net_bond1_need="net.enp0s20f2 net.enp0s20f3"
mode_bond0="balance-tlb"
mode_bond1="balance-tlb"

I am now currently setting up a core router instance (with OpenBSD 6.1) and a OpenNebula instance (with Gentoo AMD64/musl libc).

Solar Cluster: First virtual instances running

So, since my last log, I’ve managed to tidy up the wiring on the cluster, making use of the plywood panel at the back to mount all my DC power electronics, and generally tidying everything up.

I had planned to use a SB50 connector to connect the cluster up to the power supply, so made provisions for this in the wiring harness. Turns out, this was not necessary, it was easier in the end to just pull apart the existing wiring and hard-wire the cluster up to the charger input.

So, I’ve now got a spare load socket hanging out the front, which will be handy if we wind up with unreliable mains power in the near future since it’s a convenient point to hook up 12V appliances.

There’s a solar power input there ready, and space to the left of that to build a little control circuit that monitors the solar voltage and switches in the mains if needed. For now though, the switching is done with a relay that’s hard-wired on.

Today though, I managed to get the Ceph clients set up on the two compute nodes, and while virt-manager is buggy where it comes to RBD pools. In particular, adding a RBD storage pool doesn’t work as there’s no way to define authentication keys, and even if you have the pool defined, you find that trying to use images from that pool causes virt-manager to complain it can’t find the image on your local machine. (Well duh! This is a known issue.)

I was able to find a XML cheat-sheet for defining a domain in libvirt, which I was then able to use with Ceph’s documentation.

A typical instance looks like this:

<domain type='kvm'>
  <!-- name of your instance -->
  <name>instancename</name>
  <!-- a UUID for your instance, use `uuidgen` to generate one -->
  <uuid>00ec9b97-c49a-45f8-befe-f74ad6bde2fe</uuid>
  <memory>524288</memory>
  <vcpu>1</vcpu>
  <os>
    <type arch="x86_64">hvm</type>
  </os>
  <clock sync="utc"/>
  <devices>
    <emulator>/usr/bin/qemu-system-x86_64</emulator>
    <disk type='network' device='disk'>
      <source protocol='rbd' name="poolname/image.vda">
        <!-- the hostnames or IPs of your Ceph monitor nodes -->
        <host name="s0.internal.network" />
        <host name="s1.internal.network" />
        <host name="s2.internal.network" />
      </source>
      <target dev='vda'/>
      <auth username='libvirt'>
        <!-- the UUID here is what libvirt allocated when you did
	    `virsh secret-define foo.xml`, use `virsh secret-list`
	    if you've forgotten what that is. -->
        <secret type='ceph' uuid='23daf9f8-1e80-4e6d-97b6-7916aeb7cc62'/>
      </auth>
    </disk>
    <disk type='network' device='cdrom'>
      <source protocol='rbd' name="poolname/image.iso">
        <!-- the hostnames or IPs of your Ceph monitor nodes -->
        <host name="s0.internal.network" />
        <host name="s1.internal.network" />
        <host name="s2.internal.network" />
      </source>
      <target dev='hdd'/>
      <auth username='libvirt'>
        <secret type='ceph' uuid='23daf9f8-1e80-4e6d-97b6-7916aeb7cc62'/>
      </auth>
    </disk>
    <interface type='network'>
      <source network='default'/>
      <mac address='11:22:33:44:55:66'/>
    </interface>
    <graphics type='vnc' port='-1' keymap='en-us'/>
  </devices>
</domain>

Having defined the domain, you can then edit it at will in virt-manager. I was able to switch the network interface over to using virtio, plop it on a bridge so it was wired up to the correct VLAN and start the instance up.

I’ve since managed to migrate 3 instances over, namely an estate database, Brisbane Area WICEN’s OwnCloud site, and my own blog.

These are sufficient to try the system out. I’m already finding these instances much more responsive, using raw Ceph even, than the original server.

My next move I think will be to see if I can get corosync/heartbeat to manage a HA VM instance. That is, if one of the compute nodes goes offline, the instance restarts on the other compute node.

Two services come to mind where HA is concerned: terminating the PPPoE link for our Internet, and a virtual management node for a higher-level system such as OpenNebula. OpenNebula really needs something semi-HA, since it really gets its knickers in a twist if the master node goes down. I also want my border router to be HA, since I won’t necessarily be around to migrate it to a different node.

Everything else, well I suspect OpenNebula can itself manage those, and long term the instances I just liberated today from my old box, will become instances within OpenNebula.

The other option is I dip my toe into OpenStack (again), since it is inherently HA by design, but it is also a royal pain to get working.

Solar Cluster: Rack installed in-situ

So, there’s some work still to be done, for example making some extension leads for the run between the battery link harness, load power distribution and the charger… and to generally tidy things up, but it is now up and running.

On the floor, is the 240V-12V power supply and the charger, which right now is hard-wired in boost mode. In the bottom of the rack are the two 105Ah 12V AGM batteries, in boxes with fuses and isolation switches.

The nodes and switching is inside the rack, and resting on top is the load power distribution board, which I’ll have to rewire to make things a little neater. A prospect is to mount some of this on the back.

I had a few introductions to make, introducing the existing pair of SG-200 switches to the newcomer and its VLANs, but now at least, I’m able to SSH into the nodes, access the IPMI BMC and generally configure the whole box and dice.

With the exception of the later upgrade to solar, and the aforementioned wiring harness clean-ups, the hardware-side of this dual hardware/software project, is largely complete, and this project now transitions to being a software project.

The plan from here:

  • Update the OSes… as all will be a little dated. (I might even blow away and re-load.)
  • Get Ceph storage up and running. It actually should be configured already, just a matter of getting DNS hostnames sorted out so they can find eachother.
  • Investigating the block caching landscape: when I first started the project at work, it was a 3-horse race between Facebook’s FlashCache, bcache and dmcache. Well, FlashCache is no more, replaced by EnhancedIO, and I’m not sure about the rest of the market. So this needs researching.
  • Management interfaces: at my workplace I tried Ganeti, OpenNebula and OpenStack. This again, needs re-visiting. OpenNebula has moved a long way from where it was and I haven’t looked at the others in a while. OpenStack had me running away screaming, but maybe things have improved.

Solar cluster: Software stack beginning to take shape.

So, after putting aside the charge controller for now, I’ve taken some time to see if I can get the software side of things into shape.

In the midst of my development, I found a small wiring fault that was responsible for blowing a couple of fuses. A small nick in the sheath of the positive wire in a power cable was letting the crimp part of a DC barrel connector contact +12V. A tweak of that crimp and things are back to normal. I’ve swapped all the 10A fuses for 5A ones, since the regulators are only rated at 7.5A.

The VLANs are assigned now, and I have bonding going between the two pairs of Ethernet devices. In spite of the switch only supporting 4 LAGs, it seems fine with me doing LACP on effectively 10 LAGs. I’ll see how it goes.

The switch has 5 ports spare after plugging in all 5 nodes and a 16-port switch for the IPMI subnet. One will be used for a management interface so I can plug a laptop in, and the others will be paired with LACP for linking to my two existing Cisco SG200-8s.

One of the goals of this project is to try and push the performance of Ceph. In the office, we tried bare Ceph, and found that, while it’s fine for sequential I/O, it suffers a bit with random read/writes, and Windows-based HyperV images like to do a lot of random reads/writes.

Putting FlashCache in the mix really helped, but I note now, it’s no longer maintained. EnhanceIO had only just forked when I tried FlashCache, now it seems that’s the official successor.

There are two alternatives to FlashCache/EnhanceIO: bcache and dm-cache.

I’ll rule out bcache now as it requires the backing image be “formatted” for use. In other words, the backing image is not a raw image, but some proprietary (to bcache) format. This isn’t unworkable, but it raises concerns with me about portability: if I migrate a VM, do I need to migrate its cache too, or is it sufficient to cleanly shut down and detach the bcache device before re-assembling it on the new host?

By contrast, dm-cache and EnhanceIO/FlashCache work with raw backing images, making them much more attractive. Flush the cache before migration or use writethru mode, and all should be fine. dm-cache does however require a separate metadata device: messy, but not unworkable. We can provision the cache-related devices we need using LVM2, and use the kernel-mode Rados block device as our backing image.

So I think my caching subsystem is a two-horse race: dm-cache or EnhanceIO. I guess we’ll give them a try and see how they go.

For those following along at home, if you’re running kernel >4.3, you might want use this fork of EnhanceIO due to changes in the kernel block I/O layer.

To manage the OpenNebula master node, I’ve installed corosync/pacemaker. Normally these are used with DR:BD, however I figure Ceph can fulfil that role. The concepts are similar: it’s a shared block device. I’m not sure if it’ll be LXC, Docker or a VM at this point that “contains” the server, but whatever it is, it should be possible for it to have its root FS and data on Ceph.

I’m leaning towards LXC for this. Time for some more experimentation.

Solar cluster: Measuring for a cabinet

One elephant in the room, is how I’m going to store the system whilst in operation.

The obvious solution is some sort of metal cabinet with provision for 19″ rack mounting and DIN rail equipment. Question is, how big?

A big consideration here is thermal matters. When going flat out, there will be 100W-150W worth of thermal energy being dissipated in there. So room for convection currents is a must!

Some decent fans on the top to suck the hot air out would also be a good idea. Blowing up so that dust doesn’t get sucked down into the works.

I figured I’d sit everything sort-of in situ. I figured out that the DIN rail mounts don’t have to go on the bottom, with these cases, if you remove the front panel there’s four holes for mounting those same DIN rail mounts on the front. So that’s what I’ve done. I’ve now got a DIN rail spare for future expansion.

If I try to pack everything up as densely as possible (not wise), this is what it looks like:

There’s room there for possibly one more node to squeeze in there. I’d think that’d be pushing it however. 5 is probably a good number, meaning we can space the units out a bit to allow them to draw air in via the gaps.

On top of the units I have my two switches. The old Netcomm 24-port switch was retired from our network when a lightning strike to a neighbour’s tree an 8-port switch, my Yaesu FT-897D radio transceiver, some ports on a wireless 3G router/switch, and an ADSL router out. It also did damage some ports on the big Netcomm switch, so in short, I know it has issues.

Replacing its 3.3V PSU with one that steps down from 12V would cost me the price of a 16-port 10/100Mbps switch brand new.

When we replaced the switch (paid for by insurance) we decided to buy a 8-port and 16-port switch. The 16-port switch, retired due to an upgrade to gigabit, is sitting on top, and takes 12V 1A input. It’ll be perfect for the IPMI VLAN, where speed is not important. It also accepts the DC plugs I bought by mistake.

The 8-port one takes 7.5V 1A, so a little less convenient for this task, I’d need to make a DC-DC converter for it. Maybe later if this works.

So considering a cabinet for this, we have:

  • 5 nodes measuring 190mm in height: ~5 RU
  • A 24-port switch: 1 RU
  • A 16-port switch: 1 RU
  • Some power distribution electronics: 3RU

Yes, the battery and its charger is external to the cabinet.

Judging from this, the cabinet probably needs to be a 10RU or 12RU cabinet to give us space for mounting everything cleanly and to ensure good ventilation. Using 8-port IPMI switches and 24+2-port comms switches, that leaves us with sufficient port space for the 5 nodes and gives us one port left for a small in-chassis monitoring device and 4 ports left on the main switch for an uplink trunk.

You could conceptually then consider these as homogeneous building blocks for larger networks, using Ceph’s CRUSH maps to ensure copies get distributed amongst these “cabinets”.